A software tool for calculating energy efficiency for a variety of industrial and manufacturing applications.

MEASUR helps manufacturers increase industrial energy efficiency at the plant-level and in specific systems. Learn step-by-step ways to identify opportunities, monitor progress, and improve efficiency in any facility. Some tools help facilities implement an energy management system and prepare to become ISO 50001 and Superior Energy Performance certified. Based on older Department of Energy (DOE) tools, the Advanced Manufacturing Office (AMO) has undertaken this effort to refactor the legacy tools into a modern environment.
The suite includes 7 energy system assessment modules, a Data Exploration Module, extensive help text, comprehensive reports, data visualization, and 79 calculators!

Release Notes v1.2.2
MEASUR is a supported application, updates are expected and may impact previously created assessments.
Warnings:

  • Installing v1.0.0 or an earlier version of this tool will automatically reset your app data. Data can be imported into an earlier version from v1.0.0
  • Do not install an earlier version of this tool without resetting your app data (in settings).
  • Assessments created in MEASUR 0.8.0 or later are not compatible with older versions.
  • Exporting from v.0.8.0 and importing to a lower version will continue to work, though new features will not be available.

What’s New?

  • Improved UI for mobile devices for all calculators
  • Added Process Cooling Calculators into Treasure Hunt
  • Several bug fixes in Steam Assessments

Here are the details of what’s new in version 1.2.2:

Application

  • Fixed: Resetting examples will no longer delete copied examples
  • Fixed: Several issues causing missing icons and visual artifacts on MEASUR load
  • Fixed: Sidebar collapses when navigating into a folder

Calculators

  • Enhanced: Added a new field for the Tank Insulation Calculator, Surface Temperature, for use when insulation is present to better estimate energy savings
  • Enhanced: Improved UI for mobile devices for all remaining calculators
  • Fixed: Bug in web version causing calculation errors in pipe insulation calculator
  • Fixed: Cash Flow calculator’s reset button was not operable and added a "Generate Example" button
  • Fixed: Issue where lighting replacement calculator's baseline was uneditable
  • Fixed: Issues relating to the layout of the pre-assessment screening calculator
  • Fixed: Unnecessary $ units in energy use graph within Pre-assessment screening calculator

Data Explorer

  • Fixed: Bug relating to not being able to set y-axis data

Pumps

  • Fixed: Bug relating to the validation of VFD compressors
  • Fixed: Visual bug in explore Opps

Process Heating

  • Fixed: Wrong unit labels for hourly CO2 emissions (was kg instead of t)

Steam

  • Enhanced: Changed pressure of condensate flash tank to be atmospheric, not the deaerator pressure
  • Enhanced: Changed validation on Condensate Return Temperature to be based on low pressure header, instead of deaerator
  • Fixed: Added padding on steam diagram sidebar to ensure that "Calculate Marginal Costs" button is available
  • Fixed: Certain Explore Opportunities check boxes not saving
  • Fixed: Explore Opps > Adjust Boiler Conditions > Change Fuel Type was displaying outdated fields
  • Fixed: Incorrect validation warnings for low pressure header pressure
  • Fixed: Issue creating errors when start a steam assessment in imperial then switch to metric without entering data
  • Fixed: Issue where data for medium pressure steam was not saving

Treasure Hunt

  • Added: Chiller Performance Calculator
  • Added: Chiller Staging Calculator
  • Added: Cooling Tower Basin heater Energy Calculator
  • Added: Cooling Tower Fan Calculator
  • Added: Cooling Tower Makeup Water Calculator

Known Issues:

  • The Linux release does not support Auto-updating
  • Renaming an export in Windows Download menu can delete the file extension (.json)
  • Assessments made in a previous major release may experience errors
  • Import files made in a previous major release may not be useable due to field additions/removals

Release Notes v1.2.1
MEASUR is a supported application, updates are expected and may impact previously created assessments.
Warnings:

  • Installing v1.0.0 or an earlier version of this tool will automatically reset your app data. Data can be imported into an earlier version from v1.0.0
  • If MEASUR freezes during installation or fails to install, uninstall the previous version of MEASUR and repeat installation of the new installer.
  • Do not install an earlier version of this tool without resetting your app data (in settings).
  • Assessments created in MEASUR 0.8.0 or later are not compatible with older versions.
  • Exporting from v.0.8.0 and importing to a lower version will continue to work, though new features will not be available.

What’s New?

  • New compressed air control type (VFDs)
  • Compressed air end uses & Sankey
  • Compressed air energy losses Sankey
  • Added Hydrogen to carbon emissions and process heating fuels lists

Here are the details of what’s new in version 1.2.1:

Application

  • Added: Hydrogen to "Other Fuels" for carbon emissions lists
  • Added: Links to web and download versions in tool
  • Enhanced: Customized the value change of a single arrow stroke for each field across the application
  • Fixed: Bug keeping MEASUR from loading properly in Firefox
  • Fixed: Bug relating to exported custom materials not importing properly
  • Fixed: Bug relating to horizontal scroll bar showing up unnecessarily
  • Fixed: Dropdown chevrons for auxiliary pages (settings, custom materials, about, acknowledgements, etc.) all facing same direction
  • Fixed: General code clean relating the calculator icon CSS
  • Fixed: Missing assessment check for data update for new releases
  • Fixed: Several bugs relating to web version pages not loading properly
  • Fixed: Tweaks to visual style of home page and side bar

Calculators

  • Enhanced: Changed the background color of lighting and motor calculators
  • Enhanced: Improved speed to psychrometric calculator graph calculations
  • Fixed: Bug causing bins fields to disappear after clicking "Clear Bins" in Weather Bins Calculator
  • Fixed: Bug relating to psychrometric calculator freezing when entering values into barometric pressure

Data Explorer

  • Added: 3-second and 4-second interval for less-than-minute data intervals
  • Fixed: Bug relating to first datapoint for each data being removed from dataset
  • Fixed: Bugs related to 1-minute data intervals

Compressed Air

  • Added: End Uses data inputs and report
  • Added: End Uses/ Air Flow Sankey
  • Added: Energy Use Sankey
  • Added: Filter reset button
  • Added: New control type for compressors - VFD
  • Added: Validation for system profile, power and capacity percent maximums
  • Enhanced: System profile data can be entered in 15 minute and 30 minute intervals
  • Fixed: Bug relating to consistence use of atmospheric pressure value used in EEM calculations
  • Fixed: Bug relating to report graphs showing incorrect data
  • Fixed: Bug where new compressed air assessments always saved to "All Assessments" instead of specified folder
  • Removed: Field for input temperature - not used
  • Updated: Example to illustrate End Use and Air Flow Sankey

Pumps

  • Fixed: Issue with pump example not loading correctly
  • Fixed: Issue with Sankey rendering slowly
  • Fixed: Label for "Head" in Specific Speed Calculator changed to "Head per Stage"

Fans

  • Fixed: Bug relating to compressibility factor
  • Fixed: Issue with Sankey rendering slowly

Process Heating

  • Added: Hydrogen to common gas fuels list
  • Fixed: Bug causing "Common Result Unit" not correctly set results
  • Fixed: Extra decimals appearing in Custom Materials compositions
  • Removed: Unnecessary fields from Assessment Settings (Fuel, Electricity, Steam Energy Unit settings)

Treasure Hunt

  • Added: Filter reset button
  • Fixed: Cleaned up filter and sort bar buttons

Motor Inventory

  • Added: Filter reset button

Process Cooling

  • Added: Validation to process cooling calculators
  • Removed: Unnecessary sub-header in Chiller Staging

Known Issues:

  • The Linux release does not support Auto-updating
  • Renaming an export in Windows Download menu can delete the file extension (.json)
  • Assessments made in a previous major release may experience errors
  • Import files made in a previous major release may not be useable due to field additions/removals